UPS | UP1000 SERIES
1kVA-10kVA
The UPS | UP1000 series employs high frequency on-line technology for the most critical applications. Under normal mains conditions the UPS will use the incoming mains to supply power to inverter and charge the batteries.
Areas of Usage
- General Description
- Technical Specifications
- Documents
1kVA – 10kVA The UP1000 series employs high frequency on-line technology for the most critical applications. Under normal mains conditions the UPS will use the incoming mains to supply power to inverter and charge the batteries. The inverter supplies power to the load. When the utility supply is not available, then the inverter continues operating as before but now sources power from the battery. Therefore there is no switching during power disturbances and the result is an extremely stable supply.
|
- UP101 1000VA
- UP102 2000VA
- UP1030 3000VA
- UP1060 6000VA
- UP1010 10000VA
TECHNICAL SPECIFICATIONS (UP1000 1000VA) |
||||
MODEL |
UP101 |
|||
Phase |
Single phase with ground |
|||
Capacity |
1000VA / 800W |
|||
INPUT |
||||
Nominal Voltage |
200/208/220/230/240VAC |
|||
Input voltage range |
110-300 VAC at 50% load / l 60-280¥ AC at 100% load |
|||
Frequency range |
40 Hz ~ 70 Hz |
|||
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|||
OUTPUT |
||||
Output Voltage |
200/208/220/230/240VAC |
|||
Voltage regulation |
± 1% |
|||
Frequency Range (Synchronised Range) |
47~ 53 Hz |
|||
Frequency Range (Batt. Mode) |
50 Hz ± 0.25 Hz |
|||
Current Crest Ratio |
3:1 |
|||
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) |
|||
Transfer time: AC to DC |
Zero |
|||
Transfer time: Inverter to Bypass |
4 ms (Typical) |
|||
Waveform (Batt. Mode) |
Pure Sinewave |
|||
EFFICIENCY |
||||
To AC Mode |
88% |
|||
To Battery Mode |
83% |
|||
BATTERY |
||||
Standard Model |
||||
Battery Type |
12 V / 9 Ah |
|||
Numbers |
2 |
|||
Typical Recharge Time |
4 hours recover to 90% capacity |
|||
Charging Current (max.) |
1.0 A |
|||
Charging Voltage |
27.4VDC ± 1% |
|||
Long-run Model** |
||||
Battery Numbers |
Depending on the capacity of external batteries |
|||
Charging Current (max.) |
1A-6A (Adjustable) |
|||
Charging Voltage |
|
|||
INDICATORS |
||||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|||
ALARM |
||||
Battery Mode |
Sounding every 4 seconds |
|||
Alarm relays |
Sounding every second |
|||
Remote EPO input |
Sounding twice every second |
|||
Operating temperature |
Continuously sounding |
|||
PHYSICAL |
||||
Standard Model |
||||
Dimensions DxWxH (mm) |
282 x 145 x 220 |
|||
Net Weight (Kgs) |
9.8 |
|||
Long-run Model** |
||||
Dimensions DxWxH (mm) |
282 x 145 x 220 |
|||
Net Weight (Kgs) |
4.1 |
|||
ENVIRONMENT |
||||
Humidity |
20-90 % RH @ 0- 40°C (Non-condensing) |
|||
Noise Level |
Less than 50dBA @ 1 Meter |
|||
MANAGEMENT |
||||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|||
Optional SNMP |
Power management from SNMP manager and web browser |
|||
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 2000VA) |
||||
MODEL |
UP102 |
|||
Phase |
Single phase with ground |
|||
Capacity |
2000VA / 1600W |
|||
INPUT |
||||
Nominal Voltage |
200/208/220/230/240VAC |
|||
Input voltage range |
110-300 VAC at 50% load / l 60-280¥ AC at 100% load |
|||
Frequency range |
40 Hz ~ 70 Hz |
|||
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|||
OUTPUT |
||||
Output Voltage |
200/208/220/230/240VAC |
|||
Voltage regulation |
± 1% |
|||
Frequency Range (Synchronised Range) |
47~ 53 Hz |
|||
Frequency Range (Batt. Mode) |
50 Hz ± 0.25 Hz |
|||
Current Crest Ratio |
3:1 |
|||
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) |
|||
Transfer time: AC to DC |
Zero |
|||
Transfer time: Inverter to Bypass |
4 ms (Typical) |
|||
Waveform (Batt. Mode) |
Pure Sinewave |
|||
EFFICIENCY |
||||
To AC Mode |
88% |
|||
To Battery Mode |
85% |
|||
BATTERY |
||||
Standard Model |
||||
Battery Type |
12 V / 9 Ah |
|||
Numbers |
4 |
|||
Typical Recharge Time |
4 hours recover to 90% capacity |
|||
Charging Current (max.) |
1.0 A |
|||
Charging Voltage |
54.7 VDC ±1% |
|||
Long-run Model** |
||||
Battery Numbers |
Depending on the capacity of external batteries |
|||
Charging Current (max.) |
1A-6A (Adjustable) |
|||
Charging Voltage |
|
|||
INDICATORS |
||||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|||
ALARM |
||||
Battery Mode |
Sounding every 4 seconds |
|||
Alarm relays |
Sounding every second |
|||
Remote EPO input |
Sounding twice every second |
|||
Operating temperature |
Continuously sounding |
|||
PHYSICAL |
||||
Standard Model |
||||
Dimensions DxWxH (mm) |
397 x 145 x 220 |
|||
Net Weight (Kgs) |
17 |
|||
Long-run Model** |
||||
Dimensions DxWxH (mm) |
397 x 145 x 220 |
|||
Net Weight (Kgs) |
6.8 |
|||
ENVIRONMENT |
||||
Humidity |
20-90 % RH @ 0- 40°C (Non-condensing) |
|||
Noise Level |
Less than 50dBA @ 1 Meter |
|||
MANAGEMENT |
||||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|||
Optional SNMP |
Power management from SNMP manager and web browser |
|||
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 3000VA) | |||||
MODEL | UP1030 | ||||
Phase | Single phase with ground | ||||
Capacity | 3000VA / 2400W | ||||
INPUT | |||||
Nominal Voltage | 200/208/220/230/240VAC | ||||
Input voltage range | 110-300 VAC at 50% load / l 60-280¥ AC at 100% load | ||||
Frequency range | 40 Hz ~ 70 Hz | ||||
Power factor | ≥0.99 @ Nominall Voltage (100% load) | ||||
OUTPUT | |||||
Output Voltage | 200/208/220/230/240VAC | ||||
Voltage regulation | ± 1% | ||||
Frequency Range (Synchronised Range) | 47~ 53 Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz | ||||
Current Crest Ratio | 3:1 | ||||
Harmonic Distortion | ≤ 3 % THD (Linear Load) | ||||
Transfer time: AC to DC | Zero | ||||
Transfer time: Inverter to Bypass | 4 ms (Typical) | ||||
Waveform (Batt. Mode) | Pure Sinewave | ||||
EFFICIENCY | |||||
To AC Mode | 90% | ||||
To Battery Mode | 88% | ||||
BATTERY | |||||
Standard Model | |||||
Battery Type | 12 V / 9 Ah | ||||
Numbers | 6 | ||||
Typical Recharge Time | 4 hours recover to 90% capacity | ||||
Charging Current (max.) | 1.0 A | ||||
Charging Voltage | 82.1 VDC ±1% | ||||
Long-run Model** | |||||
Battery Numbers | Depending on the capacity of external batteries | ||||
Charging Current (max.) | 1A-6A (Adjustable) | ||||
Charging Voltage |
| ||||
INDICATORS | |||||
LCD | Load level, Battery level, AC mode, Battery mode and Fault indicators | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Alarm relays | Sounding every second | ||||
Remote EPO input | Sounding twice every second | ||||
Operating temperature | Continuously sounding | ||||
PHYSICAL | |||||
Standard Model | |||||
Dimensions DxWxH (mm) | 421 x 190 x 318 | ||||
Net Weight (Kgs) | 27.6 | ||||
Long-run Model** | |||||
Dimensions DxWxH (mm) | 397 x 145 x 220 | ||||
Net Weight (Kgs) | 7.4 | ||||
ENVIRONMENT | |||||
Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) | ||||
Noise Level | Less than 50dBA @ 1 Meter | ||||
MANAGEMENT | |||||
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser | ||||
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 6000VA) |
||
MODEL |
UP1060 |
|
Phase |
Single phase with ground |
|
Capacity |
6000VA / 4800W |
|
INPUT |
||
Nominal Voltage |
208/220/230/240VAC |
|
Input voltage range |
110-300 VAC(50% load}l 76-300VAC at 100% load |
|
Frequency range |
46~54 Hz or 56~64 Hz |
|
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|
OUTPUT |
||
Output Voltage |
208/220/230/240VAC |
|
Voltage regulation |
± 1% |
|
Frequency Range (Synchronised Range) |
46~54 Hz |
|
Frequency Range (Batt. Mode) |
50 Hz |
|
Current Crest Ratio |
3:1 |
|
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load) |
|
Transfer time: AC to DC |
Zero |
|
Transfer time: Inverter to Bypass |
Zero |
|
Waveform (Batt. Mode) |
Pure Sinewave |
|
EFFICIENCY |
||
To AC Mode |
92% |
|
To Battery Mode |
90% |
|
BATTERY |
||
Standard Model |
||
Battery Type |
12 V / 9 Ah |
|
Numbers |
16 |
|
Typical Recharge Time |
9 hours recover to 90% capacity |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
Long-run Model** |
||
Battery Numbers |
Depending on the capacity of external batteries |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
INDICATORS |
||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|
ALARM |
||
Battery Mode |
Sounding every 4 seconds |
|
Alarm relays |
Sounding every second |
|
Remote EPO input |
Sounding twice every second |
|
Operating temperature |
Continuously sounding |
|
PHYSICAL |
||
Standard Model |
||
Dimensions DxWxH (mm) |
369 x 190 x 688 |
|
Net Weight (Kgs) |
63 |
|
Long-run Model** |
||
Dimensions DxWxH (mm) |
369 x 190 x 318 |
|
Net Weight (Kgs) |
12 |
|
ENVIRONMENT |
||
Humidity |
0-95% RH @ 0-50°C (non-condensing) |
|
Noise Level |
Less than 55dBA @ 1 Meter |
|
MANAGEMENT |
||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|
Optional SNMP |
Power management from SNMP manager and web browser |
|
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 10 000VA) |
||
MODEL |
UP1010 |
|
Phase |
Single phase with ground |
|
Capacity |
10 000VA / 8000W |
|
INPUT |
||
Nominal Voltage |
208/220/230/240VAC |
|
Input voltage range |
110-300 VAC(50% load}l 76-300VAC at 100% load |
|
Frequency range |
46~54 Hz or 56~64 Hz |
|
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|
OUTPUT |
||
Output Voltage |
208/220/230/240VAC |
|
Voltage regulation |
± 1% |
|
Frequency Range (Synchronised Range) |
46~54 Hz |
|
Frequency Range (Batt. Mode) |
50 Hz |
|
Current Crest Ratio |
3:1 |
|
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load) |
|
Transfer time: AC to DC |
Zero |
|
Transfer time: Inverter to Bypass |
Zero |
|
Waveform (Batt. Mode) |
Pure Sinewave |
|
EFFICIENCY |
||
To AC Mode |
93% |
|
To Battery Mode |
91% |
|
BATTERY |
||
Standard Model |
||
Battery Type |
12 V / 9 Ah |
|
Numbers |
16 |
|
Typical Recharge Time |
9 hours recover to 90% capacity |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
Long-run Model** |
||
Battery Numbers |
Depending on the capacity of external batteries |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
INDICATORS |
||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|
ALARM |
||
Battery Mode |
Sounding every 4 seconds |
|
Alarm relays |
Sounding every second |
|
Remote EPO input |
Sounding twice every second |
|
Operating temperature |
Continuously sounding |
|
PHYSICAL |
||
Standard Model |
||
Dimensions DxWxH (mm) |
442 x 190 x 688 |
|
Net Weight (Kgs) |
66 |
|
Long-run Model** |
||
Dimensions DxWxH (mm) |
442 x 190 x 318 |
|
Net Weight (Kgs) |
16 |
|
ENVIRONMENT |
||
Humidity |
0-95% RH @ 0-40°C (non-condensing) |
|
Noise Level |
Less than 58dBA @ 1 Meter |
|
MANAGEMENT |
||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|
Optional SNMP |
Power management from SNMP manager and web browser |
|
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |