UPS | MY-UP100 Series. The New single phase MY-UP100 Series is a true online, dual conversion, digitally controlled UPS and utilises a transformerless with IGBT rectifier. It is designed to withstand all types of loads found typically in Telecom, Local Area Networks, E-Business, Data Centre, Point of Sale and Security applications.
Areas of Usage
- General Description
- Technical Specifications
- Documents
The MY-UP100 series conforms to the following standards: ISO9001 GENERAL SPECIFICATIONS: Green Power:
Flexible Rear Panel Configuration:
User-friendly and Easy-shift LCD Display:
|
- MY-UP100 SERIES (6000VA)
- MY-UP100 SERIES (10 000VA)
- MYUP100 6000VA
MY-UP100 SERIES TECHNICAL SPECIFICATIONS |
|||
MODEL |
MY-UP100 (6000VA) |
||
INPUT | |||
Voltage (VAC) |
80-275 (175-275@100% load) |
||
Frequency (Hz) | 50/60± 10% (50/60Hz auto-sensing) | ||
Power Factor |
≥0.99 |
||
THDi |
<5% | ||
OUTPUT | |||
Capacity (VA) |
6000 |
||
Max. AC/AC Efficiency | 95.5% | ||
Power Factor |
0.9 (1.0 optional) |
||
Voltage (VAC) |
208/220/230/240±1% (settable on display panel) |
||
Frequency (Hz) |
50/60±0.2% (battery mode) (settable on display panel) |
||
THDv |
THD <1% (linear load), THD < 4% (nonlinear load) |
||
Transfer Time (ms) |
0 |
||
BATTERY | |||
Voltage (Vdc) | 192~240 |
||
Battery Type |
16×9AH 12V/External (16~20 units settable) | ||
Charging Current (A) MAX | 1~8 adjustable | ||
OTHER | |||
Communication Interface | RS232, EPO, USB (slot) |
||
LCD Display | AC input & output voltage, frequency, load level, battery level, temperature; AC mode, battery mode, bypass mode, and fault |
||
Alarm | Low battery, abnormal AC input, UPS failure, etc. | ||
Protection | Low battery, overload, short-circuit and over temperature, etc. | ||
Noise (dB) | < 55 | ||
Working Temperature (°C) | -5~40 | ||
Relative Humidity | 0 ~ 95%, no condensation |
||
Dimensions (WxDxH) (mm) | 438×500×2U (UPS)+ 438×500×3U (Batt. pack)/438×500×2U (UPS) | ||
Weight (Kg) |
10.6+45/10.6 | ||
* Specification is subject to change without prior notice • Information is provided for reference purpose only and constitutes neither an offer or an acceptance. |
- MYUP100 10 000VA
MY-UP100 SERIES TECHNICAL SPECIFICATIONS |
|||
MODEL |
MY-UP100 (10 000VA) |
||
INPUT | |||
Voltage (VAC) |
80-275 (175-275@100% load) |
||
Frequency (Hz) | 50/60± 10% (50/60Hz auto-sensing) | ||
Power Factor |
≥0.99 |
||
THDi |
<5% | ||
OUTPUT | |||
Capacity (VA) |
10 000 |
||
Max. AC/AC Efficiency | 95.5% | ||
Power Factor |
0.9 (1.0 optional) |
||
Voltage (VAC) |
208/220/230/240±1% (settable on display panel) |
||
Frequency (Hz) |
50/60±0.2% (battery mode) (settable on display panel) |
||
THDv |
THD <1% (linear load), THD < 4% (nonlinear load) |
||
Transfer Time (ms) |
0 |
||
BATTERY | |||
Voltage (Vdc) | 192~240 |
||
Battery Type |
16×9AH 12V/External (16~20 units settable) | ||
Charging Current (A) MAX | 1~8 adjustable | ||
OTHER | |||
Communication Interface | RS232, EPO, USB (slot) |
||
LCD Display | AC input & output voltage, frequency, load level, battery level, temperature; AC mode, battery mode, bypass mode, and fault |
||
Alarm | Low battery, abnormal AC input, UPS failure, etc. | ||
Protection | Low battery, overload, short-circuit and over temperature, etc. | ||
Noise (dB) | < 55 | ||
Working Temperature (°C) | -5~40 | ||
Relative Humidity | 0 ~ 95%, no condensation |
||
Dimensions (WxDxH) (mm) | 438×500×2U (UPS)+ 438×500×3U (Batt. pack)/438×500×2U (UPS) | ||
Weight (Kg) |
12.2+45/12.2 | ||