UPS | GP3000 SERIES
10kVA - 100kVA 3-phase UPS online double conversion
The UPS | GP3000 is a 3-phase galvanic-transformer based UPS which is designed to withstand unconventional types of loads such as motors, heaters, lazers and compressors found typically in the military, manufacturing, medical, print, and laboratory environments.
Areas of Usage





- General Description
- Technical Specifications
- Documents
10kVA – 100kVA 3-3 The GP3000 is a 3-phase galvanic-transformer based UPS which is designed to withstand unconventional types of loads such as motors, heaters, lazers and compressors found typically in the military, manufacturing, medical, print, and laboratory environments. Benefits:
|
- GP3010 10kVA
- GP3015 15kVA
- GP3020 20 kVA
- GP3030 30kVA
- GP3040 40kVA
- GP3060 60kVA
- GP3080 80kVA
- GP30101 100kVA
TECHNICAL SPECIFICATIONS (GP3000 10kVA) |
|
MODEL |
GP3010 |
Power (kVA) |
10kVA / 8kW |
INPUT |
|
Normal Voltage |
3 x 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 400 VAC (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
89% |
Battery Mode |
90% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
656 x 405 x 817 |
Net weight (kg) |
118 |
TECHNICAL SPECIFICATIONS (GP3000 15kVA) |
|
MODEL |
GP3015 |
Power (kVA) |
15kVA / 12kW |
INPUT |
|
Normal Voltage |
3 x 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 400 VAC (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
89% |
Battery Mode |
90% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
656 x 405 x 817 |
Net weight (kg) |
120 |
TECHNICAL SPECIFICATIONS (GP3000 20kVA) |
|
MODEL |
GP3020 |
Power (kVA) |
20kVA / 16kW |
INPUT |
|
Normal Voltage |
3 x 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 400 VAC (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
91% |
Battery Mode |
91% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
656 x 405 x 817 |
Net weight (kg) |
145 |
TECHNICAL SPECIFICATIONS (GP3000 30kVA) |
|
MODEL |
GP3030 |
Power (kVA) |
30kVA / 24kW |
INPUT |
|
Normal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 380 VAC |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
91% |
Battery Mode |
91% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
821 x 432 x 1159 |
Net weight (kg) |
278 |
TECHNICAL SPECIFICATIONS (GP3000 80kVA) |
|
MODEL |
GP3080 |
Power (kVA) |
80kVA / 64kW |
INPUT |
|
Normal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 380 VAC |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
92% |
Battery Mode |
93% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
975 x 554 x 1286 |
Net weight (kg) |
489 |
TECHNICAL SPECIFICATIONS (GP3000 60kVA) |
|
MODEL |
GP3060 |
Power (kVA) |
60kVA / 48kW |
INPUT |
|
Normal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 380 VAC |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
92% |
Battery Mode |
93% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
975 x 554 x 1286 |
Net weight (kg) |
416 |
TECHNICAL SPECIFICATIONS (GP3000 80kVA) |
|
MODEL |
GP3080 |
Power (kVA) |
80kVA / 64kW |
INPUT |
|
Normal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 380 VAC |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
93% |
Battery Mode |
93% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
975 x 554 x 1286 |
Net weight (kg) |
489 |
TECHNICAL SPECIFICATIONS (GP3000 100kVA) |
|
MODEL |
GP30101 |
Power (kVA) |
100kVA / 80kW |
INPUT |
|
Normal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Acceptable Voltage Range |
285VAC – 475 VAC |
Frequency |
50Hz / 60Hz , ± 5% |
INVERTER |
|
Nominal Voltage |
3 x 380VAC / 400VAC (3Ph + N) |
Precision |
Stationary: ± 1 % Transitory: ±5% (load variations 100-0-100%) |
Precision |
<50/60Hz synchronised +-1 % / with mains absent +-0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load); <5% (Non-linear Load) |
Phase Displacement |
120° +-1 %(balanced load); +-2% (50% of the load imbalanced) |
Dynamic Recovery Time |
3 cycles at 90% of the static value |
Admissible Overload |
110% for 1 0min, 150% for 60sec, > 160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ l00% |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
|
Type |
Solid state |
Voltage |
3 x 380VAC I 400VAC (3Ph + NJ |
Frequency |
50Hz / 60Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissable Overload |
150% for 1 hour, 180% for 30 sec, >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
|
Type |
Without interruption |
Voltage |
3 x 380 VAC |
Frequency |
50/60 Hz |
Overall Efficiency – Line Mode |
92% |
Battery Mode |
93% |
Battery Type and Numbers |
12VDC x 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Default 10A, Max: 40A |
Charging Voltage |
432VDC (Based on 32pcs batteries) |
PHYSICAL |
|
Dimensions (mm) HxWxD |
975 x 554 x 1286 |
Net weight (kg) |
554 |