Single Phase Online UPS: 1~10kVA
UPS | UP1000 PRO SERIES 1000-10 000VA
(1-1) Phase: 1- 10kVA
UUPS | UP1000 PRO Series. The New single phase UP1000 PRO Series is a full range double conversion UPS. Firstly it’s a high density, true double conversion on-line power protection for IT (Information technology) and OT (operation technology) applications, secondly it’s capable of supporting loads from 1 to 10kVA in a compact tower form. Moreover this latest range of UPS’s come with future-proof connectivity design, having the capability to connect to cloud seamlessly to allow the monitoring of the UPS online through any internet connected device. Finally, to ensure users information is safe and protected, connectivity is compliant with IEC standard cybersecurity.
Areas of Usage
- General Description
- Technical Specifications
- Documents
The New single phase UP1000 PRO Series is a full range double conversion UPS. Firstly it’s a high density, true double conversion on-line power protection for IT (Information technology) and OT (operation technology) applications, secondly it’s capable of supporting loads from 1 to 10kVA in a compact tower form.
GENERAL SPECIFICATIONS: Key features Network connected and data to cloud |
- UP1000 PRO SERIES | 1-10kVA
- UP101 1000VA
- UP102 2000VA
- UP1030 3000VA
- UP1060 6000VA
- UP1010 10000VA
TECHNICAL SPECIFICATIONS (UP1000 1000VA) |
||||
MODEL |
UP101 |
|||
Phase |
Single phase with ground |
|||
Capacity |
1000VA / 800W |
|||
INPUT |
||||
Nominal Voltage |
200/208/220/230/240VAC |
|||
Input voltage range |
110-300 VAC at 50% load / l 60-280¥ AC at 100% load |
|||
Frequency range |
40 Hz ~ 70 Hz |
|||
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|||
OUTPUT |
||||
Output Voltage |
200/208/220/230/240VAC |
|||
Voltage regulation |
± 1% |
|||
Frequency Range (Synchronised Range) |
47~ 53 Hz |
|||
Frequency Range (Batt. Mode) |
50 Hz ± 0.25 Hz |
|||
Current Crest Ratio |
3:1 |
|||
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) |
|||
Transfer time: AC to DC |
Zero |
|||
Transfer time: Inverter to Bypass |
4 ms (Typical) |
|||
Waveform (Batt. Mode) |
Pure Sinewave |
|||
EFFICIENCY |
||||
To AC Mode |
88% |
|||
To Battery Mode |
83% |
|||
BATTERY |
||||
Standard Model |
||||
Battery Type |
12 V / 9 Ah |
|||
Numbers |
2 |
|||
Typical Recharge Time |
4 hours recover to 90% capacity |
|||
Charging Current (max.) |
1.0 A |
|||
Charging Voltage |
27.4VDC ± 1% |
|||
Long-run Model** |
||||
Battery Numbers |
Depending on the capacity of external batteries |
|||
Charging Current (max.) |
1A-6A (Adjustable) |
|||
Charging Voltage |
|
|||
INDICATORS |
||||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|||
ALARM |
||||
Battery Mode |
Sounding every 4 seconds |
|||
Alarm relays |
Sounding every second |
|||
Remote EPO input |
Sounding twice every second |
|||
Operating temperature |
Continuously sounding |
|||
PHYSICAL |
||||
Standard Model |
||||
Dimensions DxWxH (mm) |
282 x 145 x 220 |
|||
Net Weight (Kgs) |
9.8 |
|||
Long-run Model** |
||||
Dimensions DxWxH (mm) |
282 x 145 x 220 |
|||
Net Weight (Kgs) |
4.1 |
|||
ENVIRONMENT |
||||
Humidity |
20-90 % RH @ 0- 40°C (Non-condensing) |
|||
Noise Level |
Less than 50dBA @ 1 Meter |
|||
MANAGEMENT |
||||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|||
Optional SNMP |
Power management from SNMP manager and web browser |
|||
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 2000VA) |
||||
MODEL |
UP102 |
|||
Phase |
Single phase with ground |
|||
Capacity |
2000VA / 1600W |
|||
INPUT |
||||
Nominal Voltage |
200/208/220/230/240VAC |
|||
Input voltage range |
110-300 VAC at 50% load / l 60-280¥ AC at 100% load |
|||
Frequency range |
40 Hz ~ 70 Hz |
|||
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|||
OUTPUT |
||||
Output Voltage |
200/208/220/230/240VAC |
|||
Voltage regulation |
± 1% |
|||
Frequency Range (Synchronised Range) |
47~ 53 Hz |
|||
Frequency Range (Batt. Mode) |
50 Hz ± 0.25 Hz |
|||
Current Crest Ratio |
3:1 |
|||
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) |
|||
Transfer time: AC to DC |
Zero |
|||
Transfer time: Inverter to Bypass |
4 ms (Typical) |
|||
Waveform (Batt. Mode) |
Pure Sinewave |
|||
EFFICIENCY |
||||
To AC Mode |
88% |
|||
To Battery Mode |
85% |
|||
BATTERY |
||||
Standard Model |
||||
Battery Type |
12 V / 9 Ah |
|||
Numbers |
4 |
|||
Typical Recharge Time |
4 hours recover to 90% capacity |
|||
Charging Current (max.) |
1.0 A |
|||
Charging Voltage |
54.7 VDC ±1% |
|||
Long-run Model** |
||||
Battery Numbers |
Depending on the capacity of external batteries |
|||
Charging Current (max.) |
1A-6A (Adjustable) |
|||
Charging Voltage |
|
|||
INDICATORS |
||||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|||
ALARM |
||||
Battery Mode |
Sounding every 4 seconds |
|||
Alarm relays |
Sounding every second |
|||
Remote EPO input |
Sounding twice every second |
|||
Operating temperature |
Continuously sounding |
|||
PHYSICAL |
||||
Standard Model |
||||
Dimensions DxWxH (mm) |
397 x 145 x 220 |
|||
Net Weight (Kgs) |
17 |
|||
Long-run Model** |
||||
Dimensions DxWxH (mm) |
397 x 145 x 220 |
|||
Net Weight (Kgs) |
6.8 |
|||
ENVIRONMENT |
||||
Humidity |
20-90 % RH @ 0- 40°C (Non-condensing) |
|||
Noise Level |
Less than 50dBA @ 1 Meter |
|||
MANAGEMENT |
||||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|||
Optional SNMP |
Power management from SNMP manager and web browser |
|||
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 3000VA) | |||||
MODEL | UP1030 | ||||
Phase | Single phase with ground | ||||
Capacity | 3000VA / 2400W | ||||
INPUT | |||||
Nominal Voltage | 200/208/220/230/240VAC | ||||
Input voltage range | 110-300 VAC at 50% load / l 60-280¥ AC at 100% load | ||||
Frequency range | 40 Hz ~ 70 Hz | ||||
Power factor | ≥0.99 @ Nominall Voltage (100% load) | ||||
OUTPUT | |||||
Output Voltage | 200/208/220/230/240VAC | ||||
Voltage regulation | ± 1% | ||||
Frequency Range (Synchronised Range) | 47~ 53 Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz | ||||
Current Crest Ratio | 3:1 | ||||
Harmonic Distortion | ≤ 3 % THD (Linear Load) | ||||
Transfer time: AC to DC | Zero | ||||
Transfer time: Inverter to Bypass | 4 ms (Typical) | ||||
Waveform (Batt. Mode) | Pure Sinewave | ||||
EFFICIENCY | |||||
To AC Mode | 90% | ||||
To Battery Mode | 88% | ||||
BATTERY | |||||
Standard Model | |||||
Battery Type | 12 V / 9 Ah | ||||
Numbers | 6 | ||||
Typical Recharge Time | 4 hours recover to 90% capacity | ||||
Charging Current (max.) | 1.0 A | ||||
Charging Voltage | 82.1 VDC ±1% | ||||
Long-run Model** | |||||
Battery Numbers | Depending on the capacity of external batteries | ||||
Charging Current (max.) | 1A-6A (Adjustable) | ||||
Charging Voltage |
| ||||
INDICATORS | |||||
LCD | Load level, Battery level, AC mode, Battery mode and Fault indicators | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Alarm relays | Sounding every second | ||||
Remote EPO input | Sounding twice every second | ||||
Operating temperature | Continuously sounding | ||||
PHYSICAL | |||||
Standard Model | |||||
Dimensions DxWxH (mm) | 421 x 190 x 318 | ||||
Net Weight (Kgs) | 27.6 | ||||
Long-run Model** | |||||
Dimensions DxWxH (mm) | 397 x 145 x 220 | ||||
Net Weight (Kgs) | 7.4 | ||||
ENVIRONMENT | |||||
Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) | ||||
Noise Level | Less than 50dBA @ 1 Meter | ||||
MANAGEMENT | |||||
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser | ||||
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 6000VA) |
||
MODEL |
UP1060 |
|
Phase |
Single phase with ground |
|
Capacity |
6000VA / 4800W |
|
INPUT |
||
Nominal Voltage |
208/220/230/240VAC |
|
Input voltage range |
110-300 VAC(50% load}l 76-300VAC at 100% load |
|
Frequency range |
46~54 Hz or 56~64 Hz |
|
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|
OUTPUT |
||
Output Voltage |
208/220/230/240VAC |
|
Voltage regulation |
± 1% |
|
Frequency Range (Synchronised Range) |
46~54 Hz |
|
Frequency Range (Batt. Mode) |
50 Hz |
|
Current Crest Ratio |
3:1 |
|
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load) |
|
Transfer time: AC to DC |
Zero |
|
Transfer time: Inverter to Bypass |
Zero |
|
Waveform (Batt. Mode) |
Pure Sinewave |
|
EFFICIENCY |
||
To AC Mode |
92% |
|
To Battery Mode |
90% |
|
BATTERY |
||
Standard Model |
||
Battery Type |
12 V / 9 Ah |
|
Numbers |
16 |
|
Typical Recharge Time |
9 hours recover to 90% capacity |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
Long-run Model** |
||
Battery Numbers |
Depending on the capacity of external batteries |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
INDICATORS |
||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|
ALARM |
||
Battery Mode |
Sounding every 4 seconds |
|
Alarm relays |
Sounding every second |
|
Remote EPO input |
Sounding twice every second |
|
Operating temperature |
Continuously sounding |
|
PHYSICAL |
||
Standard Model |
||
Dimensions DxWxH (mm) |
369 x 190 x 688 |
|
Net Weight (Kgs) |
63 |
|
Long-run Model** |
||
Dimensions DxWxH (mm) |
369 x 190 x 318 |
|
Net Weight (Kgs) |
12 |
|
ENVIRONMENT |
||
Humidity |
0-95% RH @ 0-50°C (non-condensing) |
|
Noise Level |
Less than 55dBA @ 1 Meter |
|
MANAGEMENT |
||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|
Optional SNMP |
Power management from SNMP manager and web browser |
|
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |
TECHNICAL SPECIFICATIONS (UP1000 10 000VA) |
||
MODEL |
UP1010 |
|
Phase |
Single phase with ground |
|
Capacity |
10 000VA / 8000W |
|
INPUT |
||
Nominal Voltage |
208/220/230/240VAC |
|
Input voltage range |
110-300 VAC(50% load}l 76-300VAC at 100% load |
|
Frequency range |
46~54 Hz or 56~64 Hz |
|
Power factor |
≥0.99 @ Nominall Voltage (100% load) |
|
OUTPUT |
||
Output Voltage |
208/220/230/240VAC |
|
Voltage regulation |
± 1% |
|
Frequency Range (Synchronised Range) |
46~54 Hz |
|
Frequency Range (Batt. Mode) |
50 Hz |
|
Current Crest Ratio |
3:1 |
|
Harmonic Distortion |
≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load) |
|
Transfer time: AC to DC |
Zero |
|
Transfer time: Inverter to Bypass |
Zero |
|
Waveform (Batt. Mode) |
Pure Sinewave |
|
EFFICIENCY |
||
To AC Mode |
93% |
|
To Battery Mode |
91% |
|
BATTERY |
||
Standard Model |
||
Battery Type |
12 V / 9 Ah |
|
Numbers |
16 |
|
Typical Recharge Time |
9 hours recover to 90% capacity |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
Long-run Model** |
||
Battery Numbers |
Depending on the capacity of external batteries |
|
Charging Current (max.) |
1A, 2A, 4A, 6A (Adjustable) |
|
Charging Voltage |
218.4 VDC ±1% |
|
INDICATORS |
||
LCD |
Load level, Battery level, AC mode, Battery mode and Fault indicators |
|
ALARM |
||
Battery Mode |
Sounding every 4 seconds |
|
Alarm relays |
Sounding every second |
|
Remote EPO input |
Sounding twice every second |
|
Operating temperature |
Continuously sounding |
|
PHYSICAL |
||
Standard Model |
||
Dimensions DxWxH (mm) |
442 x 190 x 688 |
|
Net Weight (Kgs) |
66 |
|
Long-run Model** |
||
Dimensions DxWxH (mm) |
442 x 190 x 318 |
|
Net Weight (Kgs) |
16 |
|
ENVIRONMENT |
||
Humidity |
0-95% RH @ 0-40°C (non-condensing) |
|
Noise Level |
Less than 58dBA @ 1 Meter |
|
MANAGEMENT |
||
Smart RS-232 / USB |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC |
|
Optional SNMP |
Power management from SNMP manager and web browser |
|
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC. **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). Product specifications are subject to change without further notice. |