3 Phase In: 10kVA - 250kVA 3-phase Out UPS
UPS | FORTE SERIES
3 Phase In: 10kVA - 250kVA 3-phase Out
UPS | Forte Series. The New 3-phase UPS FORTE series is designed to meet the highest expectations. FORTE offers excellent protection against energy quality problems whilst using the latest technologies to improve performance and security. Moreover, its user-friendly interface and touch screen LCD panel make it simple to use and control.
Areas of Usage
- General Description
- Technical Specifications
- Documents
The 3-phase Forte UPS series is a modern high-frequency design UPS, with a power factor 1 (kVA=KW), resulting in a lower cost per kW. The Forte UPS is suitable for a wide range of applications such as mining, manufacture, data-centre, laboratory, and banking thanks to a DSP controlled, 3-level inverter design. The Forte UPS reduces electrical consumption with an efficiency of up to 96.5%. The Forte series conforms to the following standards: EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950. Thermal Harmonic distortion (THD) is maintained below 4% across the range. GENERAL SPECIFICATIONS:
|
- FORTE SERIES (10-60 kVA)
- FORTE SERIES (80-250 kVA)
- 33DS10
- 33DS15
- 33DS20
- 33DS30
- 33DS40
- 33DS60
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS10 |
||
Power (kVA) |
10 |
||
Active Power |
10 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 | ||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range |
47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
60pcs 12V 7-9Ah |
||
Battery QTY COMPACT |
20 – 52 |
||
Internal Battery QTY COMPACT |
Maximum 36 x 12V 7-9Ah |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
40 x 75 x 110 |
||
Weight (w/o battery) kg STANDARD |
100 |
||
Dimensions (WxDxH) (cm) COMPACT |
27 x 80 x 103 |
||
Weight (w/o battery) kg COMPACT |
75 |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS15 |
||
Power (kVA) |
15 |
||
Active Power |
15 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range |
47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
60pcs 12V 7-9Ah |
||
Battery QTY COMPACT |
30 – 52 |
||
Internal Battery QTY COMPACT |
Maximum 36 x 12V 7-9Ah |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard | Emergency Power Off (EPO), Generator interface | ||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
40 x 75 x 110 |
||
Weight (w/o battery) kg STANDARD |
114 |
||
Dimensions (WxDxH) (cm) COMPACT |
27 x 80 x 103 |
||
Weight (w/o battery) kg COMPACT |
79 |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS20 |
||
Power (kVA) |
20 |
||
Active Power |
20 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) | ||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
60pcs 12V 7-9Ah |
||
Battery QTY COMPACT |
36 – 52 |
||
Internal Battery QTY COMPACT |
Maximum 36 x 12V 7-9Ah |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
40 x 75 x 110 |
||
Weight (w/o battery) kg STANDARD |
116 |
||
Dimensions (WxDxH) (cm) COMPACT |
27 x 80 x 103 |
||
Weight (w/o battery) kg COMPACT |
81 |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS30 |
||
Power (kVA) |
30 |
||
Active Power |
30 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) | ||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
60pcs 12V 7-9Ah |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
40 x 75 x 110 |
||
Weight (w/o battery) kg STANDARD |
122 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS40 |
||
Power (kVA) |
40 |
||
Active Power |
40 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
Voltage Range (100% Load) |
(-15%) (+20%) |
||
Voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) | ||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
60pcs 12V 7-9Ah |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
|
Others as standard |
Emergency Power Off (EPO), Generator interface |
|
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
52 x 89 x 131 |
||
Weight (w/o battery) kg STANDARD |
180 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS60 |
||
Power (kVA) |
60 |
||
Active Power |
60 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
Voltage Range (100% Load) |
(-15%) (+20%) |
||
Voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
60pcs 12V 7-9Ah |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard | Emergency Power Off (EPO), Generator interface | ||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
52 x 89 x 131 |
||
Weight (w/o battery) kg STANDARD |
202 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
- 33DS80
- 33DS100
- 33DS120
- 33DS160
- 33DS200
- 33DS250
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS80 |
||
Power (kVA) |
80 |
||
Active Power |
80 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range |
47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
– |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
67 x 77 x 165 |
||
Weight (w/o battery) kg STANDARD |
253 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS100 |
||
Power (kVA) |
100 |
||
Active Power |
100 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
– |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard | Emergency Power Off (EPO), Generator interface | ||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
|
Dimensions (WxDxH) (cm) STANDARD |
67 x 77 x 165 |
|
|
Weight (w/o battery) kg STANDARD |
285 |
|
|
Dimensions (WxDxH) (cm) COMPACT |
– |
|
|
Weight (w/o battery) kg COMPACT |
– |
|
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS120 |
||
Power (kVA) |
120 |
||
Active Power |
120 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 | ||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
– |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard | Emergency Power Off (EPO), Generator interface | ||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
85 x 80 x 185 |
||
Weight (w/o battery) kg STANDARD |
405 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS160 |
||
Power (kVA) |
160 |
||
Active Power |
160 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 | ||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
– |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
85 x 80 x 185 |
||
Weight (w/o battery) kg STANDARD |
522 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS200 |
||
Power (kVA) |
200 |
||
Active Power |
200 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
Voltage Range (100% Load) |
(-15%) (+20%) |
||
Voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
– |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
85 x 80 x 185 |
||
Weight (w/o battery) kg STANDARD |
570 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |
FORTE TECHNICAL SPECIFICATIONS |
|||
MODEL |
FORTE 33DS250 |
||
Power (kVA) |
250 |
||
Active Power |
250 |
||
INPUT |
|||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V |
||
voltage Range (100% Load) |
(-15%) (+20%) |
||
voltage Range (50% Load) |
(-45%) (+20%) |
||
Nominal Frequency (Hz) |
50 or 60 |
||
Frequency Range |
45-65Hz |
||
Input Current THD* |
<3% |
||
Input Power Factor |
0.99 |
||
OUTPUT |
|||
Output Power Factor |
1 |
||
Phase |
3Ph+N+PE |
||
Nominal Voltage |
380V / 400V / 415V (adjustable via display) |
||
Static Voltage Regulation @ 100% Linear Load |
<%1 |
||
Output Voltage THD* |
< % 2 (Linear Load) |
||
Crest Factor |
3:1 |
||
Frequency (Hz) |
50 Hz / 60 Hz |
||
Frequency Range |
± %0.01 (Battery Mode) |
||
Overload |
Online – Battery Mode: <%125 Load 10 min, |
||
Efficiency* |
Up to 96,5% (Online), 98% (Eco Mode) |
||
STATIC BYPASS LINE |
|||
Phase |
3Ph+N+PE |
||
Bypass Voltage Range |
380V / 400V / 415V (adjustable via display: -%15 +%12) |
||
Bypass Frequency Range | 47 Hz – 53 Hz (adjustable) |
||
BATTERY |
|||
Type |
Maintenance Free Lead Acid Battery |
||
Charge Current (A) |
Nominal Charge Current x 0,1 (adjustable via display) |
||
Battery QTY STANDARD |
60 |
||
Internal Battery QTY STANDARD |
– |
||
Battery QTY COMPACT |
– |
||
Internal Battery QTY COMPACT |
– |
||
Battery Protection |
Deep Discharge Protection with Auto Cut off, |
||
Battery Test |
Standard (Automatic & Manual) |
||
DISPLAY |
|||
Color Graphic Touch Screen 3,5’’ TFT |
Load %, Input / Output / Bypass Voltage, Output Power (W & VA), Output Current, Output Power Factor, Battery ± Voltage, Input / Output Frequency, DC Bus ± Voltage, Back-up Time, Internal Temperature |
||
Event Log |
500pcs (details can be checked via display) |
||
COMMUNICATION |
|||
Interface |
RS232 & RS485 MODBUS & SNMP (optional) |
||
Dry Contact Signals |
4pcs Relays configurable to; " General Alarm", "Input Failure", "Battery Failure", "Output Failure", "Bypass Active", "Output Overload", "High Temperature" Dry contact signals |
||
Others as standard |
Emergency Power Off (EPO), Generator interface |
||
ENVIRONMENTAL |
|||
Storage Temperature (°C) |
-25°C – +70°C (15 – 40°C recommended for longer battery life time) |
||
Operating Temperature (°C) |
0 – 40°C (20 – 25 °C recommended for longer battery life time) |
||
Relative Humidity |
0-%95 (non-condensing) |
||
Operating Altitude (maximum m.) |
1000 m |
||
Protection Class |
IP20 |
||
Standards |
EN 62040-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (Performance), EN 60950 |
||
PHYSICAL |
|||
Dimensions (WxDxH) (cm) STANDARD |
85 x 80 x 185 |
||
Weight (w/o battery) kg STANDARD |
600 |
||
Dimensions (WxDxH) (cm) COMPACT |
– |
||
Weight (w/o battery) kg COMPACT |
– |
||
OPTIONS |
|||
Parallel Kit, Internal/External SNMP, Split Bypass, Remote Monitoring Panel, Isolation Transformer, Battery Cabinet |
|||
* May vary depending on UPS power & Load & Environmental Conditions. |